ABB IRC5 Operating Manual page 165

Troubleshooting
Hide thumbs Also See for IRC5:
Table of Contents

Advertisement

Recommended actions
Retry again by restarting the controller using the main power
switch. Replace the faulty axis computer.
32580, Firmware re-flash started
Description
A required update of the arg firmware has started. Internal code:
[arg].
File: [arg].
Recommended actions
Wait for the re-flash to complete.
32581, Firmware re-flash completed
Description
The update of arg firmware has completed successfully. Internal
code:[arg]
Recommended actions
No action required.
32582, Firmware re-flash failed
Description
The update of arg firmware failed.
Internal error code:arg.
Recommended actions
Check other error messages for detailed explanation. Reinstall
the system.
32583, Firmware file corrupt
Description
The update of arg firmware failed.
The firmware file [arg] is corrupt.
Internal error code:arg.
Recommended actions
Reinstall the system.
32584, Firmware file not found
Description
The update of arg firmware failed.
The firmware file [arg] is not found.
Internal error code:arg.
Recommended actions
Reinstall the system.
Operating manual - Troubleshooting IRC5
3HAC020738-001 Revision: AA
32585, No Safety System Found By Axis
Computer
Description
Axis computer failed to detect the safety system.
Recommended actions
Check communication cables between the axis computer and
the safety system. Check power supply to the safety system.
Restart the controller.
32590, Firmware re-flash started
Description
A required update of the arg firmware in drive module arg has
started.
File: [arg].
Recommended actions
Wait for the re-flash to complete, this will take approximately
3.5 minutes.
32591, Firmware re-flash completed
Description
The update of arg firmware in drive module arg has successfully
completed.
Recommended actions
No action required.
32592, Firmware re-flash failed
Description
The update of arg firmware in drive module arg has failed.
Recommended actions
Check other error messages for detailed explanation. Reinstall
the system.
32593, Firmware file corrupt
Description
The update of arg firmware in drive module arg has failed.
The firmware file [arg] is corrupt.
Recommended actions
Reinstall the system.
32594, Firmware file not found
Description
The update of arg firmware in drive module arg has failed.
The firmware file [arg] is not found.
© Copyright 2005-2018 ABB. All rights reserved.
5 Troubleshooting by event log
Continues on next page
5.5 3 xxxx
Continued
165

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents