5 Troubleshooting by event log
5.10 11 xxxx
Continued
110815, Dispense Error
Description
Task: arg
arg
Value for flow2 in beaddata is out of limits.
arg
110816, Dispense Error
Description
Task: arg
arg
Value for fl1_corr in equipdata is out of limits.
arg
110817, Dispense Error
Description
Task: arg
arg
Value for fl2_corr in equipdata is out of limits.
arg
110818, Dispense Error
Description
Task: arg
arg
Not possible to change equipment in the middle of a string.
arg
110819, Dispense Error
Description
Task: arg
arg
Value for acc_max or decel_max in equipdata is too low.
arg
110820, Dispense Error
Description
Task: arg
arg
The calculated flow value is out of limits.
arg
Continues on next page
494
110821, Dispense Error
Description
Task: arg
arg
fl1_delay or fl2_delay in equipdata is out of limits.
arg
110822, Dispense Error
Description
Task: arg
arg
Value for z_offset in beaddata is out of limits.
arg
110823, Dispense Error
Description
Task: arg
arg
Size of triggdata array exceeds upper limit (10).
arg
111000, Itemsource exists
Description
Itemsource arg already exists.
Two itemsources may not have the same name.
Recommended actions
Check itemsource name at:
arg
Recovery: arg
111001, Not a valid itemsource name
Description
Name arg is not a valid itemsource name.
Recommended actions
Check itemsource name at:
arg
Recovery: arg
111002, Buffer size exceeded
Description
Fatal internal error for itemsource arg.
Recommended actions
Try system restart or system reset. Please report this error.
© Copyright 2005-2018 ABB. All rights reserved.
Operating manual - Troubleshooting IRC5