ABB IRC5 Operating Manual page 540

Troubleshooting
Hide thumbs Also See for IRC5:
Table of Contents

Advertisement

5 Troubleshooting by event log
5.11 12 xxxx
Continued
File: arg. Line: arg.
Consequences
The configuration in file will not be installed correctly.
Probable causes
The parameter is not valid.
Recommended actions
Re-edit the configuration file and reload the cfg file.
120016, Invalid arg
Description
Parameter 'arg' has an invalid value: 'arg'
Valid values: arg
arg
Consequences
The configuration in file will not be installed correctly.
Probable causes
The value might be mistyped.
540
Recommended actions
Re-edit the configuration file and reload the cfg file.
120017, Invalid Rapid Identifier
Description
The value 'arg' of parameter 'arg' for configuration instance 'arg'
is invalid.
Consequences
The configuration in file will not be installed.
Probable causes
The value might be mistyped.
Recommended actions
Correct the value of the parameter so that it complies with the
following rules:
Rules of RAPID identifiers: The length must not exceed 16
characters. The first character must be a letter (a-z or A-Z).
Subsequent characters must be letters (a-z or A-Z), digits (0-9)
or underscores (_).
© Copyright 2005-2018 ABB. All rights reserved.
Operating manual - Troubleshooting IRC5