5 Troubleshooting by event log
5.8 7 xxxx
Continued
71553, Max number of device transfer instances
exceeded
Description
The I/O configuration is invalid.
The maximum number, arg, of device-transfer instances in the
I/O system has been exceeded.
Recommended actions
Modify the configuration of the I/O system (by reducing the
number of device-transfer instances or transfer information in
I/O signals) so that the maximum limit is not exceeded.
71554, Max number of signal safe levels
exceeded
Description
The I/O configuration is invalid.
The maximum number, arg, of signal safe levels in the I/O
system has been exceeded.
Recommended actions
Modify the configuration of the I/O system (by reducing the
number of signal safe levels) so that the maximum limit is not
exceeded.
71555, Invalid configuration of
TransferInputOffset and TransferOutputOffset
Description
The signal arg has both TransferInputOffset and
TransferOutputOffset set.
Consequences
The configuration has been rejected.
Recommended actions
Remove either TransferInputOffset or TransferOutputOffset.
71556, Signal cannot be transferred
Description
The signal arg has the signal type arg.
Only signals with the signal type DI or GI can be transferred
with TransferOutputOffset and only DO/GO can be transferred
with TransferInputOffset.
Consequences
The configuration has been rejected.
Recommended actions
Change the signal type or transfer another signal.
Continues on next page
398
71557, Signal transfer was defined but no internal
device was found
Description
The signal arg is being transferred but no internal device was
found.
Recommended actions
Make sure the device is defined/configured before restarting
the controller.
71558, Transfer signals overlap
Description
The signal arg and the signal arg both have transfer signal
defintions and overlap.
Consequences
The configuration has been rejected.
Recommended actions
Change the configuration so that the signals don't overlap.
71559, Transfer signal and crossconnection
overlaps
Description
The signal arg and the crossconnection arg overlaps.
Consequences
The configuration has been rejected.
Recommended actions
Make sure that no crossconnection and transfer signal overlap.
71560, Transfer signal and SYSOUT_SIG overlaps
Description
The transfer signal arg and the SYSOUT_SIG arg overlaps.
Consequences
The configuration has been rejected.
Recommended actions
Make sure that no SYSOUT_SIG and transfer signal overlap.
71561, Signal transfer has bitswapped devicemap
Description
The transfer signal arg has a bitswapped device map, which is
not allowed.
Consequences
The configuration has been rejected.
© Copyright 2005-2018 ABB. All rights reserved.