5 Troubleshooting by event log
5.8 7 xxxx
Continued
71325, Invalid network configuration
Description
The I/O configuration for network arg is invalid.
User-defined (externally loaded) Industrial Networks must not
be specified with the name Local.
This network has been rejected.
Recommended actions
Change the name of the network.
71326, Invalid device predefined type
configuration
Description
The I/O configuration for device predefined type arg is invalid.
User-defined (externally loaded) device predefined types must
not be specified for the Local network.
This device predefined type has been rejected.
Recommended actions
Change the device predefined type.
71328, Invalid name
Description
The I/O configuration is invalid.
The configuration instance arg does not comply with the rules
of RAPID identifiers.
This configuration instance has been rejected.
Recommended actions
Correct the name of the configuration instance so that it
complies with the following rules:
Rules of RAPID identifiers: The length must not exceed 16
characters. The first character must be a letter (a-z or A-Z).
Subsequent characters must be letters (a-z or A-Z), digits (0-9)
or underscores (_).
71329, Invalid network connection
Description
The I/O configuration for network arg is invalid.
Invalid connection arg is selected for the network.
Valid connections are: arg.
Consequences
This network has been rejected, and no functions depending
on it will work.
Recommended actions
Select a valid connection for the network.
Continues on next page
378
71331, Invalid network
Description
The I/O configuration for network arg is invalid.
The name of the network is not valid.
Installed valid networks are:arg.
Consequences
This network has been rejected, and no functions depending
on it will work.
Recommended actions
Correct the name for the network.
71332, Invalid recovery time
Description
The I/O configuration for the I/O device arg is invalid.
The value of the recovery time parameter arg is incorrect.
The recovery time (how often to try regaining contact with lost
I/O devices) must not be less than arg milliseconds.
This I/O device has been rejected.
Recommended actions
Correct the recovery time for the I/O device.
71333, Invalid DeviceNet baud rate
Description
The I/O configuration for DeviceNet network is invalid.
The value of the DeviceNet baud rate parameter is incorrect.
Valid DeviceNet baud rates are: 125 250 500 This network has
been rejected.
Recommended actions
Correct the baud rate for the DeviceNet network.
71336, Device command without path
Description
The I/O configuration is invalid.
No path is defined for the device command <arg>.
This device command has been rejected.
Recommended actions
Define a path for the device command.
71338, Invalid device command service identifier
Description
The I/O configuration is invalid.
The service identifier <arg> is not valid for the device command
<arg>.
Valid service identifiers are:
© Copyright 2005-2018 ABB. All rights reserved.
Operating manual - Troubleshooting IRC5