133206, Lock arg failed
Description
Locking of a resource for named device
failed. The same resource may have been
allocated by another device.
Recommended actions
1. Check in IPS config if several
IPS devices are using the same resource.
133207, arg:Val hi
Description
Value for named sensor or device has
exceeded maximum limit.
IPS has discovered an alarm
state for named sensor or device.
Recommended actions
1. Check if value for named sensor or
device is too high.
2. Check for IPS configured LIMIT-
alarms and verify that limits are OK.
133208, arg:Val lo
Description
Value for named sensor or device has
exceeded minimum limit.
IPS has discovered an alarm
state for named sensor or device.
Recommended actions
1. Check if value for named sensor or
device is too low.
2. Check for IPS configured LIMIT-
alarms and verify that limits are OK.
133209, arg:Act.val hi
Description
Actual value for named device has
exceeded maximum limit. IPS has
discovered too high actual value
compared to the setpoint value.
Recommended actions
1. Check for IPS configured DEVIATION-
alarms and verify that parameter limits
are OK.
2. Check if the sensor, used by named
Operating manual - Troubleshooting IRC5
3HAC020738-001 Revision: AA
device, is noisy.
133210, arg:Act.val lo
Description
Actual value for named device has
exceeded minimum limit. IPS has
discovered too low actual value
compared to the setpoint value.
Recommended actions
1. Check for IPS configured DEVIATION-
alarms and verify that parameter limits
are OK.
2. Check if the sensor, used by named
device, is noisy or sending values.
133211, arg:Comp. hi
Description
Regulator for named device has
compensated too much compared to the
calibrated curve and its compensations
parameter limits.
Recommended actions
1. Check in IPS config if compensation
limits for named device are too tight.
2. Check supply pressures, hoses, sensor
and transducer used by named device.
133212, arg:Comp. lo
Description
Regulator for named device has
compensated too much compared to the
calibrated curve and its compensations
parameter limits.
Recommended actions
1. Check in IPS config if compensation
limits for named device are too tight.
2. Check supply pressures, hoses, sensor
and transducer used by named device.
133213, arg:Potlife
Description
The potlife time for named device has
expired and the fluid will start to
cure! Paint equipment may be destroyed!
Start to flush system at once!