Torch supervision signal went low during welding.
Recommended actions
Check the welding equipment.
Recovery: You might want to handle errno arg in your error
handler.
110414, Weld supervision
Description
Task: arg
arg
Weld ignition supervision signal not set at start of welding.
Recommended actions
Check the power source.
Recovery: You might want to handle errno arg in your error
handler.
110415, Weld Off Supervision timeout
Description
Task: arg
arg
The ArcEst signal was not reset at the end of the weld within
the specified time. (arg seconds)
Recommended actions
Check the welding equipment and/or adjust the Weld Off timeout
value,
found in Arc Equipment Properties.
110416, Weld Off Supervision timeout
Description
Task: arg
arg
The WeldOK signal was not reset at the end of the weld within
the specified time.
(arg seconds)
Recommended actions
Check the welding equipment and/or adjust the Weld Off timeout
value,
found in Arc Equipment Properties.
110421, Gas supervision
Description
Task: arg
arg
Operating manual - Troubleshooting IRC5
3HAC020738-001 Revision: AA
Gas supervision signal went low during welding.
Seam name: arg.
Time from weld start: arg min.
Recommended actions
Check the gas equipment.
Recovery: You might want to handle errno arg in your error
handler.
110422, Water supervision
Description
Task: arg
arg
Water supervision signal went low during welding.
Seam name: arg.
Time from weld start: arg.
Recommended actions
Check the cooling water equipment.
Recovery: You might want to handle errno arg in your error
handler.
110423, Arc supervision
Description
Task: arg
arg
Arc supervision signal went low during welding.
Seam name: arg.
Time from weld start: arg.
Recommended actions
Check the welding equipment.
Recovery: You might want to handle errno arg in your error
handler.
110424, Voltage supervision
Description
Task: arg
arg
Voltage supervision signal went low during welding.
Seam name: arg
Time from weld start: arg.
Recommended actions
Check the welding equipment.
Recovery: You might want to handle errno arg in your error
handler.