40724, Save or Erase Error
Description
Task: arg.
The program module arg could not be saved or could not be
erased.
Program ref: arg.
Recommended actions
Check the spelling of the module name. Check if the module is
loaded. Recovery: arg.
40726, Reference Error
Description
Task: arg.
The reference to the load session is not valid.
Program ref: arg.
Recommended actions
Check if the specified reference is the same as in StartLoad.
Recovery: arg.
40727, Save Error
Description
Task: arg.
Missing file source arg.
Program ref: arg.
Recommended actions
Use FilePath argument to specify the file destination.
Recovery: arg.
40728, Frame Error
Description
Task: arg.
Unable to calculate new frame.
Program ref: arg.
Probable causes
The positions have not the required relations or are not specified
with enough accuracy.
Recommended actions
Check if the positions are too close or not specified with enough
accuracy.
Recovery: arg.
40731, Value Error
Description
Task: arg.
Operating manual - Troubleshooting IRC5
3HAC020738-001 Revision: AA
The value of the argument arg for signal arg is above its
maximum logical value.
Program ref: arg.
Recommended actions
Change the argument or change the maximum logical value
parameter for the signal.
Recovery: arg.
40732, Value Error
Description
Task: arg.
The value of the argument arg for signal arg is below its
minimum logical value.
Program ref: arg.
Recommended actions
Change the argument or change the min logical value parameter
for the signal.
Recovery: arg.
40733, Value Error
Description
Task: arg.
The value of the argument arg for signal arg is below the value
for argument arg.
Program ref: arg.
Recommended actions
Change the values of the arguments.
40734, Symbol Definition Error
Description
Task: arg.
The string in text table arg at index arg is too long.
Program ref: arg.
Recommended actions
Change the file for the text table and perform a system reset.
40735, Argument Error
Description
The axis is not defined.
Recommended actions
The axis has to be defined, before this instruction is executed.