71589, Fiber optics error
Description
Slot arg on device arg is signaling problems with the fiber optics,
power budget.
Consequences
The device may not work properly due to transmission
problems.
Recommended actions
Maintenance is needed of the device and or the fiber optics.
Check the fiber optic transmission chain. Replace the device
and or the fiber optic cables if the error remains.
71590, Duplicate device name on network
detected
Description
Device arg with serial number arg is involved in a name conflict
on the network. The device name on network is arg.
Consequences
It will not be possible to use the device until the conflict is
solved.
Recommended actions
Configure device with unique name on the network.
71591, Input signal update rate too high
Description
Device arg is producing input signal changes at too high rate.
Consequences
Possible loss of signal changes.
Recommended actions
Configure device to produce input changes at a lower rate by
changing to a higher 'Input Request Packet Interval' value or
change 'Connection Timeout Multiplier' to a higher value. If this
is the internal device change the corresponding parameters at
the Scanner.
71592, Transfer to/from an invalid internal slot.
Description
The signal arg has transfer to/from internal device arg that does
not fulfill the requirements for the action.
Consequences
The configuration has been rejected.
Operating manual - Troubleshooting IRC5
3HAC020738-001 Revision: AA
Probable causes
Transfer to/from a safety slot, Transfer from a slot with input
size 0 and Transfer to a slot with output size 0.
Recommended actions
Make sure that neither of the probable causes are true. When
using RobotStudio, only internal devices that fulfill the
requirements are shown.
71593, Firmware upgraded
Description
Device arg with serial number arg has been upgraded with new
firmware.
71594, Firmware upgrade failed
Description
Device arg with serial number arg has failed during upgrade or
check of firmware versions.
Consequences
Old versions of firmware are still in use at the device.
Probable causes
Loss of power or connectivity.
Recommended actions
Try again.
71595, Firmware upgrade available
Description
Device arg with serial number arg has got a new firmware
version available.
Consequences
Bugs are fixed or new functionality is added.
Recommended actions
Manually upgrade the device.
71596, No SFTP fingerprint configured
Description
Mounting device on remote host arg was done without checking
fingerprint.
Protocol: arg.
Using the default fingerprint configuration, no secure verification
of remote host has been done.
Fingerprint received: arg.