Link Change - Siemens SIMATIC NET SCALANCE SC-600 Configuration Manual

Industrial ethernet security web based management (wbm)
Hide thumbs Also See for SIMATIC NET SCALANCE SC-600:
Table of Contents

Advertisement

4.4.15.2

Link Change

Configuration of fault monitoring of status changes on connections
On this page, you configure whether or not an error message is triggered if there is a
status change on a network connection.
If connection monitoring is enabled, an error is signaled
• when there should be a link on a port and this is missing.
• or when there should not be a link on a port and a link is detected.
A fault causes the fault LED on the device to light up and, depending on the
configuration, can trigger a trap or an entry in the event log table.
Description
Table 1 has the following columns:
• 1st column
Shows that the settings are valid for all ports.
• Setting
Select the setting from the drop-down list. You have the following setting options:
– "-" (disabled)
– Up
– Down
– No Change: The setting in table 2 remains unchanged.
• Copy to Table
If you click the button, the setting is adopted for all ports of table 2.
SCALANCE SC-600 Web Based Management (WBM)
Configuration Manual, 10/2021, C79000-G8976-C475-03
Configuring with Web Based Management
4.4 "System" menu
209