Link Change - Siemens SCALANCE XB-200 Web Based Management

Industrial ethernet switches
Hide thumbs Also See for SCALANCE XB-200:
Table of Contents

Advertisement

Configuring with Web Based Management
5.4 The "System" menu
5.4.15.2

Link Change

Configuration of fault monitoring of status changes on connections
On this page, you configure whether or not an error message is triggered if there is a status
change on a network connection.
If connection monitoring is enabled, an error is signaled
● when there should be a link on a port and this is missing.
● or when there should not be a link on a port and a link is detected.
A fault causes the fault LED on the device to light up and, depending on the configuration,
can trigger a trap, an e-mail, or an entry in the event log table.
Description of the displayed boxes
Table 1 has the following columns:
● 1st column
Shows that the settings are valid for all ports.
● Setting
Select the setting from the drop-down list. You have the following setting options:
– "-" (disabled)
– Up
– Down
– No Change: The setting in table 2 remains unchanged.
● Copy to Table
If you click the button, the setting is adopted for all ports of table 2.
118
SCALANCE XB-200 Web Based Management
Configuration Manual, 04/2015, C79000-G8976-C360-02