Program
Program Name
Number
84-19-05
SIP Extension CODEC
Information Basic Setup – G.711
Jitter Buffer (average)
84-19-06
SIP Extension CODEC
Information Basic Setup – G.711
Jitter Buffer (max)
84-19-07
SIP Extension CODEC
Information Basic Setup –
Number of G.729 Audio Frames
84-19-08
SIP Extension CODEC
Information Basic Setup – G.729
Voice Activity Detection Mode
84-19-09
SIP Extension CODEC
Information Basic Setup – G.729
Jitter Buffer (min)
84-19-10
SIP Extension CODEC
Information Basic Setup – G729
Jitter Buffer (average)
84-19-11
SIP Extension CODEC
Information Basic Setup – G729
Jitter Buffer (max)
84-19-17
SIP Extension CODEC
Information Basic Setup – Jitter
Buffer Mode
84-19-18
SIP Extension CODEC
Information Basic Setup – VAD
Threshold
84-19-26
SIP Extension CODEC
Information Basic Setup – TX
Gain
2 - 1312
Description/Comments
Use this program to define G.711
Jitter Buffer average accepted value
– values are set in ms.
Use this program to define G.711
Jitter Buffer maximum accepted value
– values are set in ms.
Use this program to define the G.729
audio Frame Size.
Use this program to Enable or
Disable Voice Activity Detection for
G.729.
Use this program to define G.729
Jitter Buffer minimum accepted value
– values are set in ms.
Use this program to define G.729
Jitter Buffer average accepted value
– values are set in ms.
Use this program to define G.729
Jitter Buffer maximum accepted value
– values are set in ms.
Use this program to define the Jitter
Buffer mode – supported Static or
Immediate.
Use this program to define the VAD
Threshold – Values set in db. Consult
the UNIVERGE SV8100
Programming Manual for Threshold
scale to set acceptable values.
Use this program to define to TX Gain
Values – Adjusting this value
increases or decreases volume levels
for the receiving party. Consult the
UNIVERGE SV8100 Programming
Manual for Transmit Gain scale to set
acceptable value.
UNIVERGE SV8100
Assigned Data
0~160 ms
(default = 40 ms)
0~160 ms
(default = 80 ms)
1~6
1 = 10 ms
2 = 20 ms
3 = 30 ms
4 = 40 ms
5 = 50 ms
6 = 60 ms
(default = 2)
0 = Disabled
1 = Enabled
(default = 0)
0~270 ms
(default = 20 ms)
0~270 ms
(default = 40 ms)
0~270 ms
(default =80 ms)
1 = Static
2 = Adaptive during
Silence
3 = Adaptive
Immediately
(default = 3)
0~30
(default = 20)
0~40 =
(-20dbm ~ +20dbm)
0 =-20 dbm
1 =-19 dbm
:
20 =0 dbm
:
39 =+19 dbm
40 =+20 dbm
(default =20)