NEC Univerge SV8100 Features And Specifications Manual page 1294

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

Issue 1.0
Program
Program Name
Number
80-04-04
Call Progress Tone Detector
Setup – No Tone Time
80-04-05
Call Progress Tone Detector
Setup – Pulse Count
80-04-06
Call Progress Tone Detector
Setup – ON minimum time
80-04-07
Call Progress Tone Detector
Setup – ON maximum time
80-04-08
Call Progress Tone Detector
Setup – OFF minimum time
80-04-09
Call Progress Tone Detector
Setup – OFF maximum time
2 - 1270
Description/Comments
Use to define the no tone time for
the Call Progress Tone Detector.
Use to define the pulse count for
the Call Progress Tone Detector.
Use to define the on minimum time
for the Call Progress Tone Detector.
Use to define the on maximum time
for the Call Progress Tone Detector.
Use to define the off minimum time
for the Call Progress Tone Detector.
Use to define the off maximum time
for the Call Progress Tone Detector.
UNIVERGE SV8100
Assigned Data
0~255 (30+30-7680ms)
default:
Type 1 (DT) – 132
(3990ms)
Type 2 (BT) – 132
(3990ms)
Type 3 (RBT) – 132
(3990ms)
Type 4, Type 5 – 0
1~255
default:
Type 1 (DT) – 1
Type 2 (BT) – 1
Type 3 (RBT) – 1
Type 4, Type 5 – 0
1~255 (30+30-7680ms)
default:
Type 1 (DT) – 9
(300ms)
Type 2 (BT) – 9 (300ms)
Type 3 (RBT) – 25
(780ms)
Type 4, Type 5 – 0
0~255 (30+30-7680ms)
default:
Type 1 (DT) – 0
Type 2 (BT) – 14
(450ms) [ET]
Type 3 (RBT) – 40
1230ms)
Type 4, Type 5 – 0
1~255 (30+30-7680ms)
default:
Type 1 (DT) – 1 (60ms)
Type 2 (BT) – 9 (300ms)
Type 3 (RBT) – 83
(2520ms)
Type 4, Type 5 – 0
0~255 (30+30-7680ms)
default:
Type 1 (DT) – 1 (60ms)
Type 2 (BT) – 14
(450ms)
Type 3 (RBT) – 115
(3480ms)
Type 4, Type 5 – 0
Voice Mail Integration (Analog)
Level
1
2
3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents