Program
Program Name
Number
20-13-01
Class of Service Options
(Supplementary Service) – Long
Conversation Alarm
20-21-01
System Options for Long
Conversation – Long
Conversation Alarm 1
20-21-02
System Options for Long
Conversation – Long
Conversation Alarm 2
20-28-01
Trunk to Trunk Conversation –
Conversation Continue Code
20-28-02
Trunk to Trunk Conversation –
Conversation Disconnect Code
20-28-03
Trunk to Trunk Conversation –
Conversation Continue Time
21-01-01
System Options for Outgoing
Calls – Seizure Trunk Line Mode
21-01-03
System Options for Outgoing
Calls – Trunk Interdigit Time
(External)
25-07-07
System Timers for VRS/DISA –
Long Conversation Warning Tone
Time
SV8100 Features and Specifications Manual
Description/Comments
Turns Off (0) or On (1) the Warning
Tone for Long Conversation (not for
single line telephones).
After a user places a trunk call, the
system sends the first warning tone
to their extension after this time
(0~64800 seconds).
After hearing the first warning tone,
the system sends additional
warning tones after this time
(0~64800 seconds). The warning
tones continue, spaced by this time,
until the user hangs up.
Enter a single digit Continue Code
for the DISA call to use to
immediately disconnect or continue
their outside call (0~9,
or
accepted entries).
Enter a single digit Disconnect for
the DISA call to use to immediately
disconnect or continue their outside
#
call (0~9,
or
are accepted
entries).
When Program 14-01-25 is
enabled, determine the time a call is
extended when the user dials the
Continue code (defined in Program
20-28-01).
When a trunk is selected does it
select it based off the Trunk Route
Priority (0) or based off the trunk
that has not been used in the
longest time.
The system waits for this time to
expire before placing the call in a
talk state (Call Timer starts after
time expires, Voice Over and Barge-
In are not allowed until after time
expires).
Determine the time the system
should wait before the Warning
Tone is heard by DISA callers
(0~64800 seconds). If an outside
call is transferred or forwarded
off-premise using an outside trunk,
this time starts immediately. This
occurs if either trunk involved in the
call is programmed for the Warning
Tone (Program 14-01-17).
Assigned Data
0 = Off
1 = On
(default = 0 for
COS 1~15)
0~64800 (seconds)
(default = 170)
0~64800 (seconds)
(default = 180)
0~9, #,
(default not assigned)
#
are
0~9, #,
(default not assigned)
0~64800 (seconds)
(default = 0 seconds)
0 = Priority Route
1 = Circular Route
(default = 0)
0~64800 (seconds)
(default = 5 seconds)
0~64800 (seconds)
(default = 1800 seconds)