Water Cooling System - ABB GWT C9 Product Manual

Table of Contents

Advertisement

2 Product description

2.5.3 Water cooling system

2.5.3 Water cooling system
Requirements
The input and output water circuits should be equipped with manual valves. To
avoid water leaks, it is recommended to install a bleeder system in order to release
the pressure in the cooling circuit before maintenance operation.
Parameter
Maximal pressure
Maximal temperature at inlet
Minimal temperature at inlet
Minimal water flow through transformer
Minimal water flow through each arm
Minimal filtration
i
42
i
Cooling water must be free of contaminants. The flow passages in the welding gun can become
blocked by contaminants causing restricted water flow and overheating. Use only neutral water
without chlorides, sulfates etc.
WARNING
To ensure the lifetime of diodes in the transformer, the transformer must be
cooled in the correct way by water flow.
Welding without water supply, or with predefined values lower than minimal water
flow, is strictly forbidden.
© Copyright 2022 ABB. All rights reserved.
Value
10 bar
30°C
10°C
5 l/min
2.5 l/min
0.2 mm
Product manual - GWT C9
3HAA010198-001 Revision: A