Tim9/12 External Trigger Synchronization - ST STM32F412 Reference Manual

Advanced arm-based 32-bit mcus
Table of Contents

Advertisement

RM0402
Particular case: OCx fast enable
In One-pulse mode, the edge detection on TIx input set the CEN bit which enables the
counter. Then the comparison between the counter and the compare value makes the
output toggle. But several clock cycles are needed for these operations and it limits the
minimum delay t
If one wants to output a waveform with the minimum delay, the OCxFE bit can be set in the
TIMx_CCMRx register. Then OCxRef (and OCx) are forced in response to the stimulus,
without taking in account the comparison. Its new level is the same as if a compare match
had occurred. OCxFE acts only if the channel is configured in PWM1 or PWM2 mode.
18.3.11

TIM9/12 external trigger synchronization

The TIM9/12 timers can be synchronized with an external trigger in several modes: Reset
mode, Gated mode and Trigger mode.
Slave mode: Reset mode
The counter and its prescaler can be reinitialized in response to an event on a trigger input.
Moreover, if the URS bit from the TIMx_CR1 register is low, an update event UEV is
generated. Then all the preloaded registers (TIMx_ARR, TIMx_CCRx) are updated.
In the following example, the upcounter is cleared in response to a rising edge on TI1 input:
1.
Configure the channel 1 to detect rising edges on TI1. Configure the input filter duration
(in this example, we do not need any filter, so we keep IC1F='0000'). The capture
prescaler is not used for triggering, so it does not need to be configured. The CC1S bits
select the input capture source only, CC1S = '01' in the TIMx_CCMR1 register.
Program CC1P and CC1NP to '00' in TIMx_CCER register to validate the polarity (and
detect rising edges only).
2.
Configure the timer in reset mode by writing SMS='100' in TIMx_SMCR register. Select
TI1 as the input source by writing TS='101' in TIMx_SMCR register.
3.
Start the counter by writing CEN='1' in the TIMx_CR1 register.
The counter starts counting on the internal clock, then behaves normally until TI1 rising
edge. When TI1 rises, the counter is cleared and restarts from 0. In the meantime, the
trigger flag is set (TIF bit in the TIMx_SR register) and an interrupt request can be sent if
enabled (depending on the TIE bit in TIMx_DIER register).
The following figure shows this behavior when the auto-reload register TIMx_ARR=0x36.
The delay between the rising edge on TI1 and the actual reset of the counter is due to the
resynchronization circuit on TI1 input.
min we can get.
DELAY
RM0402 Rev 6
General-purpose timers (TIM9 to TIM14)
563/1163
591

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the STM32F412 and is the answer not in the manual?