Ipv6 Pim Register-Suppression - Allied Telesis x310-26FT Command Reference Manual

X310 series stackable access switches for alliedware plus version 5.4.6-1.x
Table of Contents

Advertisement

PIM-SM
6 C
V
OMMANDS
6
-
IPV
PIM REGISTER
SUPPRESSION

ipv6 pim register-suppression

Overview
Use this command to configure the register-suppression time, in seconds,
overriding the default of 60 seconds.
Use the no variant of this command to reset the value to its default of 60 seconds.
Syntax
ipv6 pim register-suppression <1-65535>
no ipv6 pim register-suppression
Mode
Global Configuration
Default
The default PIM-SMv6 register suppression time is 60 seconds, and is restored with
the no variant of this command.
Usage
Configuring this value modifies register-suppression time at the DR. Configuring
this value at the RP modifies the RP-keepalive-period value if the
rp-register-kat
awplus#
Examples
awplus(config)#
awplus(config)#
awplus(config)#
awplus#
awplus(config)#
C613-50103-01 REV A
Parameter
Description
<1-65535>
Register suppression on time in seconds.
command is not used.
configure terminal
ipv6 forwarding
ipv6 multicast-routing
ipv6 pim register-suppression 192
configure terminal
no ipv6 pim register-suppression
Command Reference for x310 Series
AlliedWare Plus™ Operating System - Version 5.4.6-1.x
ipv6 pim
1288

Advertisement

Table of Contents
loading

This manual is also suitable for:

X310-26fpX310-50fpX310-50ft

Table of Contents