Enhanced DS1 administration
Normally, you can't change the DS1 Circuit Pack screen unless you remove all related trunks
from their trunk group. However, if the DS1 MSP field on the System-Parameters
Customer-Options screen is y, and you are assigned the associated login permissions, you
can change some of the fields on the DS1 Circuit Pack screen without removing the related
trunks from their trunk group.
The following enhanced DS1 administration login permissions must be assigned on the
Command Permission Categories screen:
The Maintain Enhanced DS1 field must be y.
The Maintain Trunks field must be y.
The Maintain Switch Circuit Packs field must be y.
If you busy out the DS1 circuit pack, you can change the following fields: CRC, Connect,
Country Protocol, Framing Mode, Interface, Interconnect, Line Coding, and Protocol
Version. After changing these fields, you may also have to change and resubmit associated
screens.
Matching field settings on different screens
For enhanced DS1 administration, some field values on the DS1 Circuit Pack screen must be
consistent with those on other screens as shown in the table below. If you change field values
on the DS1 screen, you must change the related fields on the other screens and resubmit them.
DS1 Circuit Pack field
Line Coding
Connect
Protocol Version
Interface
Interconnect
Country Protocol
Specific combinations of settings for some of these fields are shown below.
Affected screens
Route Pattern
Access Endpoint
Signaling Group
Tone Generation
Signaling Group
Signaling Group
Signaling Group
Tone Generation
Signaling Group
Tone Generation
Setting up Digital Trunks
Issue 1 June 2005