Echo Cancellation - Avaya Communication Manager Administrator's Manual

Hide thumbs Also See for Communication Manager:
Table of Contents

Advertisement

Screen Reference
EC Direction
Direction of echo cancellation. Appears when Echo Cancellation is y on the DS1 Circuit Pack
screen.
Valid entries
inward/outward

Echo Cancellation

Appears when DS1 Echo Cancellation is y on the System-Parameters Customer-Options
screen and circuit packs support echo cancellation.
Valid entries
y/n
Near-end CSU Type
This field appears only when the DS1 circuit pack is a TN767D or TN464E or later suffix model,
the Bit Rate field is 1.544 and the Country Protocol field is 1 (U.S.). This field does not display
for all circuit packs.
Valid entries
other
integrated
898 Administrator Guide for Avaya Communication Manager
Usage
Indicate the direction of the echo that is being cancelled.
Usage
Enter y to allow echo cancellation.
Usage
Enter other if no channel service unit is attached to the
DS1 facility or if the CSU is an external unit. No options
are available on page 2 for administering an external
CSU.
Enter integrated if a 120A CSU module is attached to
the DS1 board. This integrated channel service unit
(ICSU) can accept software-administrable option
downlinks (that is, it can respond to test codes from
technician's equipment and report its status). When you
enter integrated, fields for administering options on the
ICSU appear on page 2 of the DS1 Circuit Pack screen.