Avaya Communication Manager Administrator's Manual page 112

Hide thumbs Also See for Communication Manager:
Table of Contents

Advertisement

Managing Telephones
Instructions
Set up the signaling group for remote office:
1. Type add signaling-group and the number of the group you want to add.
The
Signaling Group
Figure 35: Signaling Group screen
add signaling-group 6
Group Number
Trunk Group for Channel Selection:
Near-end Node Name:
Near-end Listen Port:
2. In the Group Type field, type H.323.
3. In the Remote Office field, type y.
4. In the Trunk Group for Channel Selection field, type the number of the trunk you set up
for the remote office.
5. In the Near-end Node Name field, identify the node name assigned to the CLAN that
supports the R300.
6. In the Far-end Node Name field, identify the node name assigned to the CLAN that
supports the R300.
7. In the Near-end Listen Port field, type a port number in the 5000-9999 range.
8. In the Far-end Listen Port field, type 1720. See Getting Started with the Avaya R300
Remote Office Communicator for more details.
9. In the RRQ field, type y.
10. Tab to the Direct IP-IP Audio Connection field on another page of this screen and type y.
11. Press Enter to save your changes.
112 Administrator Guide for Avaya Communication Manager
screen appears.
6
Group Type:
Remote Office?
Supplementary Service Protocol: _
clan
5001
LRQ Required? _
RRQ Required? y
SIGNALING GROUP
H.323
y
Max Number of NCA TSC: ___
Max number of CA TSC:
Trunk Group for NCA TSC:
6
Far-end Node Name: remote office 6
Far-end Listen Port:5055
Calls Share IP Signaling Connection?
Bypass If IP Threshold Exceeded?
Interworking Message: ________
Page 1 of 5
___
___
_
_

Hide quick links: