Connection Option As-Interface Bus (As-Interface Modules For Base Mounting) - Siemens SIRIUS ACT 3SU1 System Manual

Industrial controls, command and signaling devices pushbuttons and signaling devices
Table of Contents

Advertisement

AS-Interface 3SU14
11.9 Connecting
11.9.4

Connection option AS-Interface bus (AS-Interface modules for base mounting)

Note the following information when installing the screw glands:
● Installation of screw glands in plastic enclosure (3SU180.-.AA0-0A.): The force of 3.0 or
3.5 Nm is applied by tightening and holding together the nut (A) and screw gland (B).
● Installation of screw glands in metal enclosure (3SU185.-.AA0-0A.): The force of 3.0 or
3.5 Nm is applied by screwing the screw gland (B) directly into the enclosure. The nut (A)
is not an essential requirement. You can however screw the nut on for additional
protection.
282
SIRIUS ACT 3SU1 pushbuttons and signaling devices
System Manual, 08/2018, A5E03457306020A/RS-AK/010

Hide quick links: