RM0365
21.4
TIM2/TIM3/TIM4 registers
Refer to
The peripheral registers can be accessed by half-words (16-bit) or words (32-bit).
21.4.1
TIMx control register 1 (TIMx_CR1)
Address offset: 0x00
Reset value: 0x0000
15
14
13
Res.
Res.
Res.
Res.
Bits 15:12 Reserved, must be kept at reset value.
Bit 11 UIFREMAP: UIF status bit remapping
Bit 10 Reserved, must be kept at reset value.
Bits 9:8 CKD: Clock division
Bit 7 ARPE: Auto-reload preload enable
Bits 6:5 CMS: Center-aligned mode selection
Note: It is not allowed to switch from edge-aligned mode to center-aligned mode as long as
Bit 4 DIR: Direction
Note: This bit is read only when the timer is configured in Center-aligned mode or Encoder
Section 2.1
for a list of abbreviations used in register descriptions.
12
11
10
9
UIF
RE-
Res.
CKD[1:0]
MAP
rw
rw
0: No remapping. UIF status bit is not copied to TIMx_CNT register bit 31.
1: Remapping enabled. UIF status bit is copied to TIMx_CNT register bit 31.
This bit-field indicates the division ratio between the timer clock (CK_INT) frequency and
sampling clock used by the digital filters (ETR, TIx),
00: t
= t
DTS
CK_INT
01: t
= 2 × t
DTS
CK_INT
10: t
= 4 × t
DTS
CK_INT
11: Reserved
0: TIMx_ARR register is not buffered
1: TIMx_ARR register is buffered
00: Edge-aligned mode. The counter counts up or down depending on the direction bit
(DIR).
01: Center-aligned mode 1. The counter counts up and down alternatively. Output compare
interrupt flags of channels configured in output (CCxS=00 in TIMx_CCMRx register) are set
only when the counter is counting down.
10: Center-aligned mode 2. The counter counts up and down alternatively. Output compare
interrupt flags of channels configured in output (CCxS=00 in TIMx_CCMRx register) are set
only when the counter is counting up.
11: Center-aligned mode 3. The counter counts up and down alternatively. Output compare
interrupt flags of channels configured in output (CCxS=00 in TIMx_CCMRx register) are set
both when the counter is counting up or down.
the counter is enabled (CEN=1)
0: Counter used as upcounter
1: Counter used as downcounter
mode.
General-purpose timers (TIM2/TIM3/TIM4)
8
7
6
ARPE
CMS
rw
rw
rw
DocID025202 Rev 7
5
4
3
2
DIR
OPM
URS
rw
rw
rw
rw
1
0
UDIS
CEN
rw
rw
596/1080
618
Need help?
Do you have a question about the RM0365 and is the answer not in the manual?
Questions and answers