Figure 177. Clearing Timx Ocxref - STMicroelectronics RM0365 Reference Manual

Advanced arm-based 32-bit mcus
Table of Contents

Advertisement

Advanced-control timers (TIM1)
Note:
In case of a PWM with a 100% duty cycle (if CCRx>ARR), then OCxREF is enabled again at
the next counter overflow.
499/1080

Figure 177. Clearing TIMx OCxREF

DocID025202 Rev 7