8 ERROR CODES AND ERROR MESSAGES

8.6 Troubleshooting for monitoring

The GOT screen is blank.
The GOT Power LED is off.
The screen will come back on
by touching the display section.
System information functin
(system signal 1) is set.
reached its maximum life span.
(Compare the backlight life span and
Possible cause is GOT hardware fault.
Consult your sales representative.
1 Refer to GOT-A900 Series Operating Manual (GT Works Versio5/GT Designer Versio5 compatible
Extended • Option Functions Manual), for utility menu.
2 Refer to GT Designer help function, for details of Forced Screen Saver Enable signal.
8 - 15
The following describes the corrective action when the GOT monitoring screen is
blank.
NO
NO
NO
The backlight has
the operating time.)
NO
YES
Power on the GOT.
If the screen will come back, this means the
YES
screensaver is set.
This function can be set within the GOT utility
menu. 1
The bit of "Forces Screen Saver Enable Signal"
YES
for GOT may be on.
Check the bit status.
If bit is on, turn it off.
YES
Replace the backlight.