4 Faults and alarms
4.2 List of faults and alarms
Remedy:
- check the 24 V DC voltage supply to power unit.
- carry out a POWER ON (power off/on) for the component.
- replace the module if necessary.
Reaction upon F:
NONE (OFF1, OFF2)
Acknowl. upon F:
IMMEDIATELY (POWER ON)
F30047
Cooling unit: Cooling medium flow rate too low
Message value:
%1
Message class:
Application / technological function faulted (17)
Drive object:
B_INF, VECTOR_G
Reaction:
OFF2
Acknowledge:
IMMEDIATELY
Cause:
The flowrate of the cooling unit has fallen below the fault threshold.
Remedy:
- Check the feedback signals and parameter assignment (p0260 ... p0267).
- Check the coolant feed.
- Check the thermal conductivity of the coolant.
- Check the coolant concentration.
A30048
Power unit: External fan faulty
Message value:
-
Message class:
External measured value / signal state outside the permissible range (16)
Drive object:
B_INF, VECTOR_G
Reaction:
NONE
Acknowledge:
NONE
Cause:
The feedback signal from the external fan indicates a fault.
- fan faulty, blocked.
- feedback signal inaccurate.
Remedy:
- check the external fan and replace if necessary.
- if you are using an external fan with feedback, check its wiring (X12.2 or X13.2).
Note:
If you are using an external fan without feedback, check that the feedback terminal wiring on the power unit is
connected to ground and make this connection if necessary (X12.1/2 or X13.1/2).
A30049
Power unit: Internal fan faulty
Message value:
-
Message class:
Auxiliary unit faulted (20)
Drive object:
B_INF, VECTOR_G
Reaction:
NONE
Acknowledge:
NONE
Cause:
The internal fan has failed.
Remedy:
Check the internal fan and replace if necessary.
F30050
Power unit: 24 V supply overvoltage
Message value:
-
Message class:
Supply voltage fault (undervoltage) (3)
Drive object:
B_INF, VECTOR_G
Reaction:
OFF2
Acknowledge:
POWER ON
Cause:
The voltage monitor signals an overvoltage fault on the module.
Remedy:
- check the 24 V power supply.
- replace the module if necessary.