Commands for Status Monitoring and Statistics

configure transceiver-test window

configure transceiver-test window <1-8>
Description
Configures the number of 20-second windows within which the configured number of errors can occur.
NOTE
This command is available only on modular switches.
Syntax Description
window
Specifies the number of 20-second windows. The range is 1 to 8 20-second windows.
Default
Eight windows
Usage Guidelines
Use this feature when the switch can be brought off line.
This configuration provides a sliding window. If you keep the window configuration at 8, the switch
checks for errors within the last eight 20-second windows.
To determine the number of errors the switch accepts before it takes action, use the
configure
command.
transceiver-test threshold
Extreme Networks does not recommend changing the default transceiver test window parameter. The
default parameter is adequate for most networks.
Example
The following command configures the switch to check for errors within the last seven 20-second
windows:
configure transceiver-test window 7
History
This command was first available in ExtremeWare 6.2.2b108.
This command was not supported in ExtremeWare 7.0.
This command is supported in ExtremeWare 7.1.0.
Platform Availability
This command is available only on modular switches.