configure reboot-loop-protection

configure reboot-loop-protection threshold <time-interval> <count>
Description
Configures reboot loop protection.
Syntax Description
time-interval
count
Default
If you enter a
Usage Guidelines
Specifying a time interval of 0 disables reboot loop protection. Specifying any other value enables it. To
view the current settings, use the
If you reboot the switch manually or use the
time interval and count are both reset to 0.
Example
The following command configures the time interval to 5 minutes and the count to 4:
configure reboot-loop-protection threshold 5 4
History
This command was first available in ExtremeWare 6.2.2.
This command was added to the Summit "e" series of switches in ExtremeWare 7.2e.
Platform Availability
This command is available on all platforms.
ExtremeWare 7.5 Command Reference Guide
The length of time during which the switch can reboot the specified count before entering minimal
mode. The range is 0 - 255 minutes.
The number of reboots within the specified time-interval. The range is 1 - 7.
but not a
time-interval
show switch
, the default
count
count
or
show configuration
run msm-failover
configure reboot-loop-protection
is 3.
commands.
or
commands, the
run diagnostics