mpls signaling-interface

Syntax
Release Information
Description
Options
Mode
1410
mpls signaling-interface interfaceType interfaceSpecifier
no mpls signaling-interface
Command introduced in JunosE Release 7.1.0.
Specifies a particular layer 2 interface as the signaling interface for an MPLS major
interface that is stacked on an ATM AAL5 interface. MPLS uses the IPv4 or IPv6 interface
stacked on the specified interface for signaling. The no version restores the default
behavior, wherein MPLS nondeterministically selects a layer 2 interface as the signaling
interface.
NOTE: You can configure this command only for interfaces that use the
interface label space. For interfaces that use the platform label space, the
signaling interface is always next to the MPLS major interface, that is, stacked
on the same lower interface and is not configurable.
interfaceType—Interface type; see Interface Types and Specifiers on page 5
interfaceSpecifier—Particular interface; format varies according to interface type; see
Interface Types and Specifiers on page 5
Interface Configuration
Copyright © 2010, Juniper Networks, Inc.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the JUNOSE SOFTWARE FOR E SERIES 11.3.X - COMMAND REFERENCE A TO M 2010-10-19 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

This manual is also suitable for:

Junose 11.3

Table of Contents