mpls rsvp bfd-liveness-detection
Syntax
Release Information
Description
Options
Mode
Copyright © 2010, Juniper Networks, Inc.
{ ip | mpls } rsvp bfd-liveness-detection [ minimum-interval minInterval |
[ minimum-receive-interval minRecInterval ]
[ minimum-transmit-interval minTransInterval ] ] [ multiplier multValue ]
no { ip | mpls } rsvp bfd-liveness-detection
Command introduced in JunosE Release 8.1.0.
Enables BFD (bidirectional forwarding detection) on an interface running RSVP-TE and
defines BFD values to be negotiated between RSVP-TE neighbors for detection of IP
data path failures. The no version disables BFD on the RSVP-TE interface.
NOTE: BFD sessions might not be maintained when the multiplier value is 1
and configured intervals are very short. We recommend that you do not use
a multiplier value of 1 with very short intervals.
ip—Specifies alternative keyword for compatibility with non–E Series implementations
mpls—Specifies JunosE MPLS implementation
minInterval—Minimum proposed transmit interval and required receive interval for BFD
control packets; has the same effect as configuring the minimum receive interval and
the minimum transmit interval to the same value; number in the range 100–65535
milliseconds—for ES2 4G LM only, the range is 10–65535 milliseconds; default value
is 300 milliseconds
minRecInterval—Minimum interval at which the local peer must receive BFD control
packets sent by the remote peer; number in the range 100–65535 milliseconds—for
ES2 4G LM only, the range is 10–65535 milliseconds; default value is 300 milliseconds
minTransInterval—Minimum interval at which the local peer proposes to transmit BFD
control packets to the remote peer; number in the range 100–65535 milliseconds—for
ES2 4G LM only, the range is 10–65535 milliseconds; default value is 300 milliseconds
multValue—Detection multiplier value that the remote peer router multiplies by the
local peer's negotiated transmit interval to determine the remote peer's BFD liveness
detection interval; equal to the number of BFD packets that can be missed before the
BFD session is declared down; number in the range 1–255; default value is 3
Interface Configuration
Chapter 13: M Commands
1399
Need help?
Do you have a question about the JUNOSE SOFTWARE FOR E SERIES 11.3.X - COMMAND REFERENCE A TO M 2010-10-19 and is the answer not in the manual?