Parameters According To Status I/O; S2C235: User Output Relay When Control Power Is On; S4C000 To S4C015: Parity Of User Input Groups - YASKAWA DX100 Operator's Manual

For material handling, press tending, cutting, and other applications
Hide thumbs Also See for DX100:
Table of Contents

Advertisement

155507-1CD
DX100
8.5

8.5.0.1 S2C235: USER OUTPUT RELAY WHEN CONTROL POWER IS ON

8.5.0.2 S4C000 to S4C015: PARITY OF USER INPUT GROUPS

d15
S4C000
d15
S4C002
8
Parameter

8.5 Parameters according to Status I/O

Parameters according to Status I/O
These parameters set the parity check or I/O setting for user input/output
signals.
This parameter specifies the state of the user output relays when the
control power is turned ON. Since the power OFF state, including
peripheral devices, cannot be completely reproduced, take note when
restarting.
0
: Reset to the power OFF state
1
: Initialized (all user relays OFF)
These parameters specify whether to execute priority checks with
parameters when instructions covering the input group (1G#) are
executed. The instructions covering the input groups are as shown below.
• IF Sentence (JUMP, CALL, RET, PAUSE)
• Pattern Jump, Pattern Job Call
• DIN
• WAIT
d0
IG#01
IG#02
IG#03
IG#04
IG#05
IG#06
IG#07
IG#08
IG#09
IG#10
IG#11
IG#12
IG#13
IG#14
IG#15
IG#16
d0
IG#33
IG#34
IG#35
IG#36
IG#37
IG#38
IG#39
IG#40
IG#41
IG#42
IG#43
IG#44
IG#45
IG#46
IG#47
IG#48
Parity bits are set as the highest level bits of each input group and are
written in even parity. If an error is detected during parity check, an alarm
occurs and the manipulator stops. Remains unchanged if no parity check
is specified.
8-40
d15
S4C001

d0
IG#17
IG#18
IG#19
IG#20
IG#21
IG#22
IG#23
IG#24
IG#25
IG#26
IG#27
IG#28
IG#29
IG#30
IG#31
IG#32
471 of 554
RE-CSO-A037

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents