6.15.2.3 Analog Output Display

6
Convenient Functions
6.15 Analog Output Function Corresponding to Speed
The current settings can be confirmed on the analog output window.
Terminal
General analog output port
OUTPUT (V)
Indicates the voltage which is currently output.
BASIC (V)
Indicates the basic voltage used for the analog output corresponding to
speed.
This value is used until a new value is set by ARATION instruction.
TRAIT
Indicates the current output characteristics of the output port.
SP RAT : during execution of the analog output corresponding to speed
STATIC : fixed output status
OFFSET (V)
Indicates the offset voltage used for the analog output corresponding to
speed.
This value is used until a new value is set by ARATION instruction.
BASIC SPD
Indicates the basic speed used for the analog output corresponding to
speed.
This value is used until a new value is set by ARATION instruction.
ROBOT
Indicates the manipulator number for the analog output corresponding
to speed.
1. Select {IN/OUT} from the main menu
2. Select {ANALOG OUTPUT}
– The analog output window appears.
The output terminal numbers which follow
the AOUT4 can be switched and
displayed by pressing the page key.
6-139
379 of 554