Operation Method; Displaying A Weaving File; Editing Condition Data; Cases That Require The Registration Of Reference Points - YASKAWA DX100 Operator's Manual

For material handling, press tending, cutting, and other applications
Hide thumbs Also See for DX100:
Table of Contents

Advertisement

155507-1CD
DX100

9.3.3 Operation Method

9.3.3.1 Displaying a Weaving File

9.3.3.2 Editing Condition Data

9.3.3.3 Cases that Require the Registration of Reference Points

9
General Purpose Application
9.3 Using Files
1. Select {ARC WELDING} under the main menu.
2. Select {WEAVING}.
3. Display the desired file number.
– The weaving condition file can be displayed using the page key
GO BACK
.
PAGE
Press the page key
Press [SHIFT]+ page key
Press the page key to input the desired file number, then press enter
key.
1. Select the item to be edited.
2. Input the value using the Numeric keys.
The registration of the reference point REFP1 or REFP2 is not usually
required. They are required only with a special workpiece condition, etc.
The REFP1, which defines the wall direction, is a point on the wall surface
or its expansion plane. The REFP2, which defines the horizontal
direction, is a point at the right or left side of the wall.
REFP1
On the wall surface or
its expansion plane
Wall
REFP1
Wall direction
REFP1
Direction
of travel
For information on registering REFP, refer to section 3.2.3.2
SUPPLE-
"Registering Reference Point Instructions" on page 3-18.
MENT
9-34
GO BACK
to call the next file number.
PAGE
to call the previous file number.
GO BACK
PAGE
At the right or left side of the wall
Wall
Wall direction
REFP2
REFP2
REFP2
Direction
of travel
Horizontal
direction
523 of 554
RE-CSO-A037

Hide quick links:

Advertisement

Table of Contents
loading