User Variables - YASKAWA DX100 Operator's Manual

For material handling, press tending, cutting, and other applications
Hide thumbs Also See for DX100:
Table of Contents

Advertisement

DX100

3.9.4 User Variables

3
Teaching
3.9 Other Job-editing Functions
User variables are used for jobs to store counters, calculation results or
input signals. Since the same user variable can be used in multiple jobs,
save the numerical values as common references for the jobs and the
user variables are maintained even when the power is turned OFF.
User variables have the following applications:
• Controlling of the number of workpieces
• Controlling of the number of jobs
• Sending/receiving of information between jobs
The data formats for user variables are described in the following table:
Table 3-5: User Variables
Data
Variable No.
Format
(pcs)
B000 to B099 
Byte Type
(100)
Integer
1000 to 1099
(100)
Type
Double
D000 to D099
(100)
Precision
Integer
Type
Real Type
R000 to R099
(100)
Character
S000 to S099
(100)
Type
Position
P000 to P127
(128)
Type
BP000 to BP127
(128)
EX000 to EX127
(128)
3-77
155507-1CD
Functions
Range of storable values is from
0 to 255. 
Can store I/O status. 
Can perform logical operations
(AND, OR, etc.)
Range of storable values is from -
32768 to 32767.
Range of storable values is from -
2147483648 to 2147483647.
Range of storable values is from -
3.4E+38 to 3.4E38. 
Accuracy: 1.18E-38 < x  3.4E38
Maximum storable number of
characters is 16.
Can store position data in pulse
form or in XYZ form.
XYZ type variable can be used as
target position data for move
instructions, and as incremental
values for parallel shift
instructions.
RE-CSO-A037