DX100
6
Convenient Functions
6.9 Parameter Setting Function
• JOB UNDELETE FUNCTION(S2C413)
Refer to section 8.3.0.39 "S2C410: WORD REGISTRATION
FUNCTION / WORD EDITING FUNCTION SPECIFICATION" on
page 8-25.
Setting
Parameter Value
Invalid
0
Valid
1
• INDEPENDENT :MOTION OF NEXT/TEST(S2C231)
Refer to section 8.6.0.3 "S2C231: OPERATION METHOD AT FWD/
BWD OPERATION OR TEST RUN BY INDEPENDENT CONTROL"
on page 8-45.
This appears only when the independent control is valid.
Setting
Parameter Value
Single
0
All
1
• BWD OPERATION NO GROUP AXIS (S2C688 d0 bit)
• BWD OPERATION CONCURRENT JOB (S2C688 d1 bit)
Refer to section 8.6.0.10 "S2C688: EXECUTION OF "BWD"
OPERATION" on page 8-48.
This appears only when the independent control is valid.
Setting
Bit Status
Permit
0
Prohibit
1
• STATION TWIN (S2C434)
Refer to section 8.3.0.44 "S2C434: JOB LINKING DESIGNATION
(When Twin Synchronous Function Used)" on page 8-28.
This appears only when the STATION TWIN SYNCHRONOUS
JOB is valid.
Setting
Parameter Value
Invalid
0
Valid
1
• CLEARANCE TEACHING METHOD (S2C612)
This appears only when it is for motor gun use.
Setting
Parameter Value
Upper Tip
0
Lower Tip
1
Gun Close 2
6-98
155507-1CD
RE-CSO-A037
338 of 554