6.15.2 Instructions

6.15.2.1 Instructions for Analog Output Function Corresponding to Speed

6
Convenient Functions
6.15 Analog Output Function Corresponding to Speed
The instructions, ARATION and ARATIOF, are used for the analog output
function corresponding to speed.
ARATION
The analog output function corresponding to speed is performed after
executing ARATION instruction. This instruction is valid during circular
interpolation, linear interpolation or spline interpolation. It is executed only
at playback or FWD key operation; it is not executed during axis
operation.
This instruction is also used when each set value for the analog output
function corresponding to speed is to be changed.
ARATION AO#(1) BV=10.00 V=200.0 OFV=2.00

Output port number
General analog output port to execute the analog output corresponding
to speed
Setting range : 1 to 40
Basic voltage
Voltage to be output at the speed set with the basic speed.
Setting range : -14.00 to +14.00V
Basic speed
Operating speed which becomes the basis for when the set voltage is
output.
Setting range : 0.1 to 1500.0mm/sec
1 to 9000cm/min
Offset voltage
Analog voltage when the operating speed is 0.
Setting range : -14.00 to +14.00V
6-134