155507-1CD
DX100

4.3.3 Stop by Alarm

4
Playback
4.3 Stop and Restart
If an alarm occurs during operation, the manipulator stops immediately
and the ALARM window appears on the programming pendant indicating
that the machine was stopped by an alarm.
– If more than one alarm occurs simultaneously, all alarms can be
viewed on the window. Scroll down the viewing area of the window
when necessary.
The following operations are available in the alarm status: 
window change, mode change, alarm reset, and emergency stop. 
To display the ALARM window again when the window is changed during
alarm occurrence, select {SYSTEM INFO} and then {ALARM HISTORY}.
Releasing Alarms
<Minor Alarms>
1. Press [SELECT].
– Select "RESET" under the ALARM window to release the alarm
status.
– When using an external input signal (system input), turn ON the
"ALARM RESET" setting.
<Major Alarms>
1. Turn OFF the main power supply and remove the cause of the alarm.
– If a severe alarm such as hardware failure alarm occurs, the servo
power is automatically shut off and the manipulator stops. If
releasing does not work, turn OFF the main power and correct the
cause of the alarm.