S2C396: Variable Name Alias Function - YASKAWA DX100 Operator's Manual

For material handling, press tending, cutting, and other applications
Hide thumbs Also See for DX100:
Table of Contents

Advertisement

DX100

8.3.0.37 S2C396: VARIABLE NAME ALIAS FUNCTION

8
Parameter
8.3 Mode Operation Setting Parameters
On the JOB CONTENT window, the name registered to the variable
(including local variables) can be displayed as alias instead of the variable
number.
Table 8-5: S2C396
Parameter Setting Value
0
1
1. With this function valid, the confirmation dialog box "Register by name
(alias) ?" is displayed when you select the variable on the DETAIL
EDIT window.
2. Select "YES" and the variable select window appears. Then select the
target variable of number and press [ENTER], and the registered
name is displayed instead of the variable number. However, if the
variable number's name is not yet registered, it is displayed by number
as usual.
<Example> Registration of the byte type variable B000 as "WORK KIND" 
In the case of SET instruction 
S2C396=0 : SET B000 128 
S2C396=1 : SET WORK KIND 128
Select {VARIABLE} from the menu to select each variable
and edit the variable name. Up to 16 characters can be
entered as a variable name. However, when this function is
valid, if the content below is entered, the error message
shows and the name cannot be registered.
• The name already registered
• Letters beginning with a number
• Letters including the signs below: 
( , ) , [ , ] , = , < , > , space, comma
• Letters beginning with "alphabets representing variables" +
"number" 
<Example> B0..., I0..., BP1..., LEX2... 
SUPPLE-
MENT
When the name begins with " ' ", it is regarded as a comment
and the same comment can be registered for two or more
variables. In this case, although this function is valid, the
number is displayed on the JOB CONTENT window instead
of the name.
<Example> Registration of the byte type variable B001 as 
8-23
Valid/Invalid
Function invalid
Function valid
Alphabets representing variables: B, I, D, R, 
S, P, BP, EX, PX, LB, LI LD, LR, LS, LP, LBP, 
LEX, LPX
"WORKNUM" 
S2C396=0 : SET B001 10 
S2C396=1 : SET B001 10
155507-1CD
RE-CSO-A037
454 of 554

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents