Mitsubishi Electric GOT2000 Series Connection Manual page 1153

Graphic operation terminal
Hide thumbs Also See for GOT2000 Series:
Table of Contents

Advertisement

Step 7.
On the [PLC side I/F Detailed Setting of GOT], mark the [via GOT(Ethernet) transparent mode]
checkbox and click [Setting...].
Step 8.
By clicking [Set], the [GOT (Ethernet) Transparent Setting] is displayed.
Here, set the built-in Ethernet port QCPU or Ethernet module, which is firstly connected via a GOT.
Step 9.
Set [QnUDE(H)] or [QJ71E71] for [PLC Type].
Step 10.
Specify the number for [Network No.] and [Station No.] same as the number assigned to the Ethernet
module.
When [QnUDE(H)] is set for [PLC type], the setting is not required.
Step 11.
Specify the IP address for [IP Address] same as the IP address assigned to the built-in Ethernet port
QCPU or Ethernet module.
Step 12.
The screen returns to [Transfer Setup Connection1]. Click [Connection Test] to check if GX Works2
has been connected to the QCPU (Q mode).
22.7 Personal Computer Side Setting