Table 2.4 Recommended iView Starting Values for Initial Operation
Drive Type
Speed Reference
Speed reference scaling
Speed ref resolution
Rated motor RPM:
Coupling rotational ratio (Brake drum or Sheave Diameter/ Diameter of encoder wheel). If
Normal rate limited stop Per job. Default 1 ft/s.
Emerg rate limited stop
Following error
Pulses Per Foot
Contract Speed
Contract Overspeed
Inspection Overspeed
Leveling Overspeed
Limit One Margin
Top Access Landing
Top Access Rear
Bottom Access Landing
Bottom Access Rear
No Main String
No Main String Rear
Frnt Door Close Contact
Rear Door Close Cntact
Rear Doors
Freight Door Option 1
Rope Gripper
Car Top Exit
Construction Mode
Door Position Monitor
In Car Panel Inspection
Caution
Permanent magnet (PM) AC Gearless Machines must by synchronized with the AC Drive.
Please refer to PM Synchronous Motors > Motor Data and Loading motor data from
encoder in the Initial Start Up section of the TORQMAX F5 drive manual.
iView Screen Settings
Drive >General tab
Factory set. Verify drive type selected is correct.
Tachometer
60.000 V/k
Velocity Encoder PPR
From motor plate.
shaft mounted, set to 1.000
Per job. Default 7 ft/s.
Drive > Safety tab
25% (factory shipped default)
Safety > General tab
Display Only
Display Only
107% of Contract Speed
150 feet per minute
150 feet per minute
8%
Job specific, check job prints
Job specific, check job prints
Job specific, check job prints
Job specific, check job prints
Job specific, check job prints
Job specific, check job prints
Job specific, check job prints
Job specific, check job prints
Job specific, check job prints
Job specific, check job prints
Check to see if a rope gripper is used
Check job prints.
Set to ON.
Check if used (see job prints)
Check if used (see job prints)