Pattern - Common Tab - MCi iControl User Manual

For ac elevators
Table of Contents

Advertisement

Pattern - Common Tab

The Pattern > Common tab parameters apply to all pattern profiles.
General
• Position encoder resolution: Used to set the position encoder resolution. 256, the resolu-
tion used by iLand, is currently the only valid setting.
• Pattern scaling: Scaling factor applied to all programmed speeds. This is used during
adjustment to move the car slowly to verify drive operation, etc. May be set from 0 to
150%. At 0%, no pattern command output voltage is produced so the car should not move.
At 100%, the car will move at the high speed set for the selected operating mode.
• Door pre-opening distance: When set, this is the distance from the final floor position at
which door pre-opening is initiated. If no distance is set, door pre-opening is disabled.
Configuration - Pattern
9
9-129

Advertisement

Table of Contents
loading