System Options

Additional iControl Settings and Procedures

Verify the following iControl settings and procedures:
1. On the iView Controller > Configuration > Load Weigher tab:
• Set Load weighing device type to Analog signal.
• Set Sensing type to Cross head deflection or rope tension sensing.
2. If the load weigher will be used to implement dispatching options, the parameters asso-
ciated with these options must be set (see Load Weigher Adjustment for Dispatching in
Section 4 of the iControl User Guide.
3. iControl needs to learn the empty and full load weights at every landing available to this
car. This is a semi-automated process (see Learning Load Values in Section 4 of the
iControl User Guide).