Door Lock - MCi iControl User Manual

For ac elevators
Table of Contents

Advertisement

iView - Controller View
• Field voltage: Actual voltage applied to the motor field. (DC only)
• Field current: Value proportional to the current flowing through the motor field (DC only).
• Brake voltage: Actual voltage applied to the brake.
• Brake current: A value proportional to the actual current flowing through the brake.

Door lock

• Front and Rear: Indicates when the front and rear door locks are made up.
Leveling sensor
• Up leveling marker (Front and Rear): Indicates when front and rear Up leveling markers
sensors are On.
• Door zone (Front and Rear): Indicates when front and rear door zone sensors are On.
• Down leveling marker (Front and Rear): Indicates when front and rear down leveling
marker sensors are On.
Pattern
• Profile:
• Alternate 1
• Alternate 2
• Correction
• Phase: (Please see the graphic below)
• Idle
• Begin Accel
• Acceleration
• End Accel
• High Speed
Faults
• All active fault messages are displayed in the Faults list box. A complete listing of fault
messages is provided in Section 6.
Car status
• All active car status messages are displayed in the Car status list box. A complete listing of
status messages is provided in Section 6.
9-10 Manual # 42-02-2222
Emergency Power
Earthquake
Emergency slowdown
Begin Decel
Deceleration
Flare
Approach
Leveling
Please refer to "iControl Messages" on page 6-13.
Please refer to "iControl Messages" on page 6-13.
Idle