iView - System View
• General outputs
• General - Attendant service output: Active when the specified car is on Attendant Ser-
vice operation. Select Car ID in Association column.
• General - Fire service phase I output: Active during Fire Recall Phase I. Association
column is blank.
• Manual configuration inputs
• Manual config - Hall call configuration input: Selects the Hall call eligibility configura-
tion (1 - 8) designated in the Association column to be the currently active configura-
tion.
• Manual config - Parking configuration input: Selects the Parking configuration (1 - 8)
designated in the Association column to be the currently active configuration.
• Manual config - Parking eligibility configuration input: Selects the Parking eligibility
configuration (1 - 8) designated in the Association column to be the currently active
configuration.
• Manual config - Mode of operation configuration input: Selects the Mode of operation
configuration (1 - 8) designated in the Association column to be the currently active
configuration.
• Manual config - Security configuration input: Selects the Security configuration (1 - 8)
designated in the Association column to be the currently active configuration.
• Active configuration outputs
• Active config - Hall call eligibility output: Indicates that the Hall call eligibility configu-
ration (1 - 8) designated in the Association column is the currently active configura-
tion.
• Active config - Parking output: Indicates that the Parking configuration (1 - 8) desig-
nated in the Association column is the currently active configuration.
• Active config - Parking eligibility output: Indicates that the Parking eligibility configu-
ration (1 - 8) designated in the Association column is the currently active configura-
tion.
• Active config - Mode of operation output: Indicates that the Mode of operation config-
uration (1 - 8) designated in the Association column is the currently active configura-
tion.
• Active config - Security output: Indicates that the Security configuration (1 - 8) desig-
nated in the Association column is the currently active configuration.
Security: The following inputs control how hall calls to secured floors are handled by the sys-
tem. They are typically activated from switches or buttons at the building security station so
that security personnel can easily and quickly make adjustments to hall call security as a situa-
tion demands. They can also be activated by a card reader or keypad, etc.
• Hall call enable 1 (or 2) inputs
• Hall call enable 1 (2) - Floor input: When active, a valid call for the secured floor can be
registered. Select floor number in Association column.
• Hall call enable 1 (2) - Front input: When active, a valid call for the front opening on
the associated secured floor can be registered. Select floor number in Association col-
umn.