Configuration - Advanced - Custom Outputs

The custom outputs feature allows existing inputs, outputs and internal flags to be combined in
a custom logic equation which can then generate a custom output which can be assigned to an
output terminal on an ICE-MOR or ICE-COP board.
In the simple example above, the Earthquake Buzzer, Attendant Buzzer, Fire Warning Buzzer
and Nudging Audible outputs are OR'ed into one Combined Buzzer Output, which is then
assigned to a terminal on an ICE-MOR board.
To program a custom output
1. Check the Enabled box to enable a line of the logic equation.
2. The Name of the output or flag can be customized, up to 16 characters can be used.
3. Click the Operand I cell and click the arrow. Use the
dialog box to select the Data Type and Operand Data.
Then click OK. The appropriate information is placed
in the logic table.
4. Click the Operator cell, click the arrow and select an
operator (NOT, AND, OR, XOR, NAND).
5. Click the Operand 2 cell and click the arrow. Use the
dialog box to select the Data Type and Operand Data
as in step 3.
6. Acquire Write privilege and Send the data to iControl.
7. The Status LED turns on when the logic statement is
true.
8. Once the logic equation is complete, you can assign
the custom output to a terminal using the I/O Boards
tab.
Please refer to "Configuration - I/O Boards" on
page
9-100. Outputs can be programmed for an ICE-
MOR board or for an ICE-COP board.
Configuration - Advanced - Custom Outputs
Custom outputs are programmed as follows:
9
9-139