• Main Floor Smoke: Input from the smoke sensors located at the main recall floor. Acti-
vation of these sensors will initiate recall to the alternate recall floor.
• Other Cars Alternate: Input from other car (in the same system) smoke sensors located
in the hoistway or machine room if the machine room is located at the main recall
floor. Activation of these sensors will initiate recall to the alternate recall floor.
• Other Cars Main: Input from other car (in same system) smoke sensors located in the
hoistway or machine room if the machine room is located at any floor other than the
main recall floor. Activation of these sensors will initiate recall to the main recall floor.
• Over Load Input: Input from a discrete load weigher over load output.
• Passing Floor Gong Enabled: Input, from a key switch, that enables the audible pass-
ing floor gong in the elevator car.
• Power Transfer: Input from a key switch or contact closure used to force the car to stop
at the next available floor and open its doors. This input is usually used right before
power is transferred from the emergency power generator to commercial power.
• Primary Fire Switch BYPASS: Input from a keyed switch in the building lobby, that
allows a Fire Phase I initiating device (smoke detector, fire alarm, etc.) to be bypassed
or unlatched as specified per code.
• Primary Fire Switch OFF: Input from a keyed switch in the building lobby, that termi-
nates Fire Phase I if appropriate (as specified per code).
• Primary Fire Switch ON: Input from a keyed switch in the building lobby, that initiates
Fire Phase I and recalls the car to the main fire recall floor. Recall particulars are fire
code specific. Code is selected on the Configuration > Car Operation > Fire Service tab
and particulars may be modified on the Fire code tabs.
• Recall Switch (1 through 6): One of six switches that places a car in Recall mode, recall-
ing it to an assigned floor. Switch priority, door operation, car call disposition, and
more are configured on the Configuration > Car Operation > Elevator recall tab.
refer to "Car Operation - Elevator Recall Tab" on page
• Sabbath Operation Switch: Input from a key switch used to force the car to automati-
cally service the building based on the selected floor eligibility so that the passengers
can travel from floor to floor without having to press any buttons.
• Sabbath Override Input: When this input is activated, the Sabbath Operation Switch
input is ignored and, if already activated, Sabbath Operation is cancelled.
• Secondary Fire Switch ON: Input from a keyed switch in a different location than the
Primary Fire Switch, that initiates Fire Phase I and recalls the car to the alternate fire
recall floor. Recall particulars are fire code specific.
• Shuttle Service: Input from a key switch used to turn Shuttle service On and Off.
• Shuttle Service Override: Input from a key switch used to override Shuttle service.
• Swing Automatic Operation: When activated, the car will automatically enter Swing
operation when a hall call is received from the Swing riser. Automatic Swing operation
assumes an "always active" Swing riser.
• Swing Operation Switch: Input from a key switch used to take the car out of group dis-
patching operation allowing it to service a dedicated hall call riser and perform its own
parking, hall call service and security based on the System parameters programmed
and stored on the Swing car's iBox
• This Car Alternate: Input from the smoke sensors located in the hoistway or machine
room if the machine room is located at the main recall floor and if the car has any
Configuration - I/O Boards
9-61.
(see "Automatic Swing Operation" on page
Please
9
9-39)
9-109