MCi iControl User Manual page 367

For ac elevators
Table of Contents

Advertisement

Receive Serial Data
and up to four to Serial COP boards. Each connection can be monitored by setting the S1 DIP
switches as described below:
• To monitor data received from iBox, set DIP switches 1 and 4 = ON.
• To monitor data received from COP1, set DIP switches 1, 2 and 4 = ON.
• To monitor data received from COP2, set DIP switches 1, 3 and 4 = ON.
• To monitor data received from COP3, set DIP switches 1, 2, 3 and 4 = ON.
• To monitor data received from COP4, set DIP switches 1, and 5 = ON.
When the LEDs are ON they indicate the following:
• LED1: A non-STX character has been detected when an STX character was expected.
• LED2: An STX character has been received from the cartop.
• LED3: Data characters are being received from the cartop.
• LED4: A CRC character has been received.
• LED5: The CRC check indicates that good data was received.
• LED6: The CRC check indicates that bad data was received.
In normal operation, LEDs 2, 3, and 5 will glow faintly and LED 4 will blink roughly once every
40ms. If LED 1 or 6 is bright, bad data is being received from the cartop. This suggests that
there is a serial line quality problem.
Transmit Serial Data
• To monitor data transmitted to iBox, set DIP switches 2 and 4 = ON.
• To monitor data transmitted to COP1, set DIP switches 3 and 4 = ON.
• To monitor data transmitted to COP2, set DIP switches 2, 3 and 4 = ON.
• To monitor data transmitted to COP3, set DIP switch 5 = ON.
• To monitor data transmitted to COP4, set DIP switches 2 and 5 = ON.
When the LEDs are ON they indicate the following:
• LED1: The transmitter is in the RESET condition.
• LED2: The board is sending STX characters.
• LED3: The board is sending data characters.
• LED4: The board is sending CRC characters.
• LED5: The transmitter was busy when the board attempted to send data.
In normal operation, LEDs 2, 3, and 4 will glow faintly. If either LED 1 or 5 comes on and stays
on, the board has malfunctioned. If a manual reset does not clear the problem, there is a hard-
ware problem on the ICE-CTP board.
If LEDs turn on and stay on, the board is not functioning normally and should be reset (press
the RESET button). If the condition persists, there is likely a hardware problem on the board.
iControl Circuit Board Quick References
There are five serial connections on the cartop - one to the iBox
Set the S1 DIP switches as described below:
6