• Hoistway Door Bypass: Switch used to bypass the hoistway door electric contacts (Bypass
position). When set to Bypass, the car will run only on Inspection mode. The ability to set
this bypass must be enabled at the factory and is only available if allowed by safety regula-
tions in your area. Check the iView Safety Configuration screen to see if the feature is
enabled in your installation.
INSPECTION
INSP
NORM
UP
ENABLE
DOWN
Note
These control switches are used when the elevator controller is being configured. Please refer to
Sections 3 and 4 of this guide for use descriptions.

Safety Bypass Jumper and Fuses

The iBox provides four fused outputs:
• 120v/60Hz AC: Fuses F2 and F2PI.
• 110v DC: Fuses F3 and F3HA.
• 120v/60Hz AC: Motor Drive. Fuse F2D.
• 120v/60Hz AC: Motor Contactor. Fuse F2MC.
When installed, the Safety Bypass jumper electrically connects the SB and 3 terminals on the
IRB Relay Board. Information about the Safety Bypass jumper is in Section 6 of this guide
"Safety String Bypass Jumper" on page
Danger
The fuses and the bypass jumper expose dangerous high voltages that can cause bodily
harm or death. ONLY TRAINED, AUTHORIZED PERSONNEL should have access to these
areas.
CONTROLLER
FAULT/FUNCTION
STOP
BYPASS
RUN
ON
OFF
STOP
CAPTURE
WRITE ENABLE
ON
ON
OFF
OFF
LEARN
TEST
ON
ON
OFF
OFF
CAR DOOR
HOISTWAY
BYPASS
DOOR BYPASS
BYPASS
BYPASS
OFF
OFF
6-3).
Safety Bypass Jumper and Fuses
7