Cabling Connections - MCi iControl User Manual

For ac elevators
Table of Contents

Advertisement

Cabling Connections

The Position Encoder and Leveling Sensors connect to the iLand Signal board (LS-IPH)
through short, factory-assembled cables with an RJ45 connector at each end. These cables
should already be in place and connected. If they have been removed, they need to be recon-
nected. Refer to Figure 7 for guidance.
Figure 7. iLand Cable Connections
Front Door
Leveling Sensor
iLand to
iLink Cartop
Processor
Front Door
The cables from the iLand Landing System (LS-IPH board) to the iLink Cartop Processor (ICE-
CTP board) are supplied. They should be routed through flexible conduit from the iLand con-
nectors shown in Figure 7 to the iLand Front Door and, if applicable, iLand Rear Door connec-
tors on the ICE-CTP board in the iLink Cartop Box as shown in Figure 8
on page
3-15).
Figure 8. Cartop Interconnection
Field Outputs
Discrete Car Calls
(if not Serial Car Call)
Field Inputs
Serial links to iControl
iLINK CARTOP BOX
Outputs
Inputs
Cartop Board
Load Weigher
(ICE-CTP)
Serial Car Call
Cabling Connections
(see also "iLink Wiring"
iLAND LANDING SYSTEM
Position Encoder
Sensor Board
Rear (option)
Sensor Board
Front
Signal Board
(LS-IPH)
Serial Link
Rear Door
Leveling Sensor
(optional)
Position Encoder
iLand to
iLink Cartop Pro-
cessor Rear Door
(optional)
3
Landing Zone
magnet
Landing Zone
magnet
3-11