Serial Cop Board Specifications - MCi iControl User Manual

For ac elevators
Table of Contents

Advertisement

System Options

Serial COP Board Specifications

Each Serial COP board handles up to 24 call buttons or switches. If more inputs are required,
Serial COP boards are daisy-chained together.
• Each of the Serial COP board's 24 I/O connections can be used as an input, an output or a
combined call input and output.
• Plugable connections are provided for COP buttons and switches.
• Inputs can be 12 - 24 VDC (24V preferred).
• Outputs: 24V, 6W (maximum) lamps or 250mA LEDs recommended.
• Socketed, easily replaceable drivers protect the board from damage due to out-of-range
inputs.
• The initial Serial COP board (ICE-COP) communicates with the iLink ICE-CTP board
using an RJ-11 cable.
• Additional Serial COP boards (ICE-COP-X) are daisy-chained using RJ-11/RJ-45 cables.
• All Serial COP board I/O assignments are field configurable using the iView Configuration
> I/O Boards > Configuration tab.
100. The signal types include:
• Car calls
• Car call enables (security)
• Enable overrides (security)
• Door controls
• Car status
• Position indicators
• Alarm I/O
• Load indicators
• Operating mode I/O including: Fire service, Attendant service, Independent service,
Flood operation, Inspection operation, Swing operation, Earthquake operation, Sab-
bath operation, Recall operation and CFSS (Commandeer for Special Service) opera-
tion.
5-50 Manual # 42-02-2222