MCi iControl User Manual page 717

For ac elevators
Table of Contents

Advertisement

PowerBack R6 Regenerative Drive Quick Reference
This section includes quick reference information for the PowerBack R6 Regenerative AC drive.
Please refer to the R6 Regenerative drive manual provided with the iControl for detailed expla-
nation of the parameters.
Table 11.7 Quick Reference for PowerBack R6 Regenerative Drive
WARNING: Do not change drive parameters while the elevator is running. Incorrect values of
drive parameters can cause erratic elevator operation.
Display
Parameter Description
CP. 0
Password input
CP. 1
Status display
CP. 2
Main Line Frequency
CP. 3
AC-Phase current L1
CP. 4
AC-Phase current L2
CP. 5
AC-Phase current L3
CP. 6
Actual Load
CP. 7
Actual Load / peak value
CP. 8
DC output current
CP. 9
Actual DC voltage
CP.10
DC voltage / peak value
CP.11
Heat sink temperature
CP.12
Over load counter
CP.13
Active power
CP.14
Total regen kWhr counter
CP.15
Total motor kWhr counter
CP.16
Total net kWhr counter
CP.17
Apparent power / Line input
CP.18
Analog output 1 / amplification factor
CP.19
DC bus switching level
CP.20
Auto error reset counter
CP.21
Last Error
CP.22
Last Error 1
CP.23
Last Error 2
CP.24
Last Error 3
CP.25
Last Error 4
CP.26
Last Error 5
CP.27
Last Error 6
CP.28
Last Error 7
CP.29
Software version
CP.30
Software date code
CP.31
Power part ID code
CP.32*
Pulse off Level
Operating Mode
CP.33*
0: Master with Commutation Choke
2: Slave with Commutation Choke
CP.34*
Control Angle
*NEW PARAMETERS in software version 1.3
Job #:
Production Order #
Drive Model #:
PowerBack R6 Regenerative Drive Quick Reference
Setting Range
0...9999
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
-20.00...20.00
+/- 30000.00
0...10
---
---
---
---
---
---
---
---
---
DDMM.Y
---
-100kW...0.0kW
0...3
0.0...60.0
Drive Serial #:
Test Technician:
Date:
Resolution
Field/MCE Set
1
---
0.1 Hz
0.1 A
0.1 A
0.1 A
1%
1%
0.1 A
1 V
1 V
0
1
C
1%
0.1kW
0.1 kWh
0.1 kWh
0.1 kWh
0.1 kVA
0.01
1.00
Set to 260 for 208 - 240Vac
0.01
Set to 600 for 460 - 480Vac
1
Set to 250 for 208 - 240Vac
Set to 253 for 460 - 480Vac
0.1kW
-0.8kW
Set to 0 for Main Regen drive
1
Set to 2 for Second drive
0.1
29.0
ting
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
3
---
---
---
---
---
---
---
---
11
11-31